Skip to main content
A Nanografi Nano Technology companyNanografi [email protected]

Analysis

FTIR Spectroscopy Analysis

Fourier-transform infrared spectroscopy for functional group identification, material verification and contamination analysis of polymers, coatings and powders.

In short

Fourier-transform infrared spectroscopy for functional group identification, material verification and contamination analysis of polymers, coatings and powders. FTIR analysis is performed on an Anton Paar Lyza 7000 spectrometer in the mid-infrared region using ATR (attenuated total reflectance) or transmission sampling.

FTIR analysis is performed on an Anton Paar Lyza 7000 spectrometer in the mid-infrared region using ATR (attenuated total reflectance) or transmission sampling. The infrared absorption spectrum reveals functional groups through molecular bond vibrations, enabling polymer type identification, detection of additives and fillers, monitoring of degradation signatures such as oxidation or hydrolysis, tracking of cure state and identification of unknown residues. Spectra are compared against reference libraries and customer-supplied reference samples to verify incoming materials and assess batch-to-batch consistency. The service supports quality control, supplier auditing and failure analysis in plastics, rubber, paints and coatings, adhesives, textiles, oils and lubricants, pharmaceutical and cosmetic industries, as well as academic research groups needing rapid chemical screening.

What you receive

  • Baseline-corrected ATR/transmission spectra with peak tables (cm⁻¹)

  • Functional group assignments and library match results

  • Comparison against reference sample or specification

  • Method summary covering sampling mode, resolution and number of scans

  • Raw spectral data (CSV/SPC) and PDF report

How it works

  1. Request and scoping

    The analytical objective (identification, verification, contamination), sample form and any reference material are agreed; the sampling mode is selected.

  2. Sample reception and preparation

    Samples are logged; surface contamination is removed and, where needed, cross-sections are taken or powders homogenised.

  3. Measurement

    After a background scan, sample spectra are acquired at the chosen resolution and scan count; replicate measurements confirm consistency.

  4. Reporting

    Results are presented in the standard analysis report; supporting technical documentation is shared on request.

Pricing

Available now

€240

per sample

excl. VAT (20%) · Minimum 1
Volume pricing
1+€240
5+€216
10+€192

Lead time 3–7 business days

Final pricing depends on sample count, preparation and reporting scope. You receive an itemised proposal.

Prices are a guide and may change with any additional requests. Our team will contact you to confirm the scope and the final price.

Request this service

Describe your sample and the decision it supports. We reply with a technical proposal.

Request analysis

Instruments used

FTIR
Anton Paar Lyza 7000

Questions

Frequently asked questions

How do I send samples for FTIR Spectroscopy Analysis?

Fill in the analysis request form. Our team replies with preparation and shipping instructions for your sample type, and we confirm together that the sample is suitable before you send it.

How long does FTIR Spectroscopy Analysis take?

It depends on the number of samples and laboratory workload. The estimated time on this page is a reference; once we review your request we share a firm schedule.

How is the price set?

The price on this page is a list price. It may change with the number of samples and any additional requests; after we agree the scope, the final price is shared in a proposal.

How do I receive the results?

Results are delivered as a written report. You can follow the status of your request in your account and through email notifications.

Can I request this from abroad?

Yes. We accept requests in Turkish, English, Arabic and Persian, and reply in the language you prefer.

Can I see your quality documents?

We develop our quality processes with reference to ISO/IEC 17025. For the current documents and scope details, contact us and we will send them in writing.

  • Analysis

    Raman Spectroscopy Analysis

    Non-destructive micro-Raman spectroscopy for molecular structure, phase identification, crystallinity and defect analysis of carbon and other materials.

  • Analysis

    Ash, Loss on Ignition and Moisture Analysis

    Gravimetric determination of ash content, loss on ignition, inorganic residue and moisture using a muffle furnace and a halogen moisture analyser.

  • Consulting

    Failure Analysis and Materials Consulting

    Root-cause determination of fracture, corrosion, coating delamination and product performance problems by multi-technique characterisation and expert review.

  • Characterization

    FTIR or Raman: Which Technique Fits Your Sample?

    FTIR and Raman probe the same molecular vibrations by different physics. A practical guide to choosing between them, what each needs from your sample, and how to read the resulting spectrum.

    November 9, 20267 min read

Request this service

Describe your sample and the decision it supports. We reply with a technical proposal.

Request analysis