Spectroscopy and diffraction
PerkinElmer FL 8500 Fluorescence Spectrometer
Photoluminescence characterisation of liquids, solids and powders through excitation and emission spectra, 3D fluorescence maps and quantum yield.
In short
Photoluminescence characterisation of liquids, solids and powders through excitation and emission spectra, 3D fluorescence maps and quantum yield. The PerkinElmer FL 8500 is a spectrofluorometer that combines a pulsed xenon lamp with a dual-monochromator optical design for sensitive fluorescence measurements over a wide wavelength range.
- Light source
- Pulsed xenon lamp
- Optical design
- Excitation and emission monochromators
- Wavelength range
- UV – visible – near-infrared
Services on this instrument
Fluorescence Spectroscopy Analysis
from €1403–7 business daysRequest this serviceService detailsInstrument Operator Training
from €42014–30 business daysRequest this serviceService details
Overview
The PerkinElmer FL 8500 is a spectrofluorometer that combines a pulsed xenon lamp with a dual-monochromator optical design for sensitive fluorescence measurements over a wide wavelength range. It supports excitation, emission and synchronous scans; three-dimensional fluorescence maps as excitation-emission matrices (EEM); time-based intensity measurements; and a phosphorescence mode. Cuvette, solid-sample and powder holders accommodate solutions, films, glasses, powders and ceramics, and an integrating sphere allows absolute quantum yield to be determined. The system is used in the development of luminescent materials such as quantum dots, perovskites, phosphors and organic emitters, in studies of fluorescent dyes and biomolecules, in detecting fluorescent impurities in water and food, and in spectral fingerprint comparison for quality control, with software for spectral correction, peak analysis and quantitative calibration.
Measurement principle
Capabilities
Excitation, emission and synchronous spectral scans
3D fluorescence mapping by excitation-emission matrix (EEM)
Time-based intensity and phosphorescence measurements
Absolute quantum yield determination with integrating sphere
Measurement of solutions, films, powders and solid samples
Spectral correction and quantitative calibration
Suitable samples
Quantum dot and perovskite dispersions
Phosphors and luminescent powders
Organic dye and emitter solutions
Thin films and glass samples
Biomolecules and fluorescently labelled samples
Water, food and environmental samples
Technical specifications
| Light source | Pulsed xenon lamp |
|---|---|
| Optical design | Excitation and emission monochromators |
| Wavelength range | UV – visible – near-infrared |
| Measurement modes | Excitation, emission, synchronous, EEM, time-based, phosphorescence |
| Sample accessories | Cuvette holder, solid sample holder, powder holder, integrating sphere |
| Data processing | Spectral correction, peak analysis, quantum yield calculation |
Services on this instrument
Fluorescence Spectroscopy Analysis
from €1403–7 business daysRequest this serviceService detailsInstrument Operator Training
from €42014–30 business daysRequest this serviceService details
- Manufacturer
- PerkinElmer
- Model
- FL 8500
- Catalogue no.
- 23
- Reference standards
- ASTM E388, ASTM E578
Quick answers
Fluorescence: key facts
What is PerkinElmer FL 8500 Fluorescence Spectrometer used for?
It is used for: Excitation, emission and synchronous spectral scans, 3D fluorescence mapping by excitation-emission matrix (EEM), Time-based intensity and phosphorescence measurements, Absolute quantum yield determination with integrating sphere, Measurement of solutions, films, powders and solid samples, and Spectral correction and quantitative calibration.
Which samples can PerkinElmer FL 8500 Fluorescence Spectrometer analyse?
Suitable samples: Quantum dot and perovskite dispersions, Phosphors and luminescent powders, Organic dye and emitter solutions, Thin films and glass samples, Biomolecules and fluorescently labelled samples, and Water, food and environmental samples.
Which standards does PerkinElmer FL 8500 Fluorescence Spectrometer relate to?
Relevant standards: ASTM E388 and ASTM E578.
Which NAKTEM services use PerkinElmer FL 8500 Fluorescence Spectrometer?
Fluorescence Spectroscopy Analysis and Instrument Operator Training.
What results do I receive?
Typical deliverables: Excitation and emission spectra with tables of peak wavelength, Stokes shift and bandwidth, Three-dimensional excitation–emission matrix (EEM) plots on request, Relative quantum yield against a reference standard (where applicable), Method summary covering slit widths, scan speed and detector gain, and Raw data (CSV) and PDF report.
Related services
Analysis
Fluorescence Spectroscopy Analysis
Excitation–emission spectroscopy to characterise the optical properties of fluorescent materials, quantum dots, phosphors, dyes and biological probes.
Training
Instrument Operator Training
Hands-on operator training on analytical instruments including SEM/EDS, XRD, Raman and rheometry, covering sample preparation, measurement and data interpretation.
Related instruments
Spectroscopy and diffraction
Olympus BX43F-based Confocal Micro-Raman Spectroscopy System
Laser-excited micro-Raman spectroscopy for chemical and structural identification at micrometre resolution, including phase and defect analysis of carbon materials.
Spectroscopy and diffraction
Anton Paar Lyza 7000 Fourier Transform Infrared Spectrometer (FTIR)
Functional group identification, material verification and quality control of solids, liquids and films in ATR and transmission sampling modes.
Life science
Bio-Rad C1000 Touch Thermal Cycler with CFX96 Real-Time PCR (qPCR) Optical Module
Real-time quantitative PCR in a 96-well format with five-colour multiplex fluorescence detection for gene expression, pathogen detection and genotyping.
Coating and thin film
Laurell WS-650Mz-23NPPB Programmable Spin Coater
Solution-based deposition of uniform polymer, sol-gel and nanomaterial thin films on flat substrates with controlled thickness by spin coating.
Request analysis on this instrument
Tell us about your sample and the question. Our scientists confirm feasibility and propose a measurement plan.